V-Bank Dry Cooler Air Condenser for data center office building

Changzhou ADV Heat Exchanger Co., Ltd

V-Bank Dry Cooler Air Condenser for data center office building

  • 1
  • 2

Brand Name : ADV

Model Number : ADV -UC-01

Certification : ISO9001:2008

Place of Origin : Changzhou China

MOQ : 1 Unit

Price : FOB SHANGHAI

Supply Ability : 1~50 + Units + 25 Working Days

Delivery Time : 7~15 Working Days

Packaging Details : Wooden Packing

Item : V-Bank Dry Cooler Air Condenser for data center office building

Frame : Stainless Steel,Aluminum,Copper,Titanium

Fin : Copper Fin/ Hydrophilic Fin / Epoxy Coated Fin/ Copper Tinned Fin

Fan : EC/Explosion-proof / Marine Fan/Stainless Steel Guards

Others : Fan Motor cabling /Fan Speed Control/ Fan Step Control/

Application : Data centers Office buildings Hospitals/medical office buildings Industrial/process systems Heat transfer/recuperation Power generation Induction cooling

Contact Now

V-Bank Dry Cooler Air Condenser for data center office building​

Dry coolers can play a significant role in helping a building operate more efficiently. Though this equipment is not known for conserving energy, it can be utilized as a condensing unit for a heat recovery chiller. The primary function of a heat recovery chiller is to provide heating or chilled water from energy that is normally wasted, but it can also provide chilled water to supplement a building’s primary chilled water system in the event of a shut down or failure. When a heat recovery chiller supplements a chilled water system, there must be a system to remove excess heat. This is the perfect application for a dry cooler, which serves as a condensing unit or cooling tower. In certain applications, this type of design can eliminate the need for water or air cooled chillers to be connected to the building’s back up power supply, which can potentially reduce the size of an emergency generator.

Application

  • Data centers
  • Office buildings
  • Hospitals/medical office buildings
  • Industrial/process systems
  • Heat transfer/recuperation
  • Power generation
  • Induction cooling

Quality Details

V-Bank Dry Cooler Air Condenser for data center office building

V-Bank Dry Cooler Air Condenser for data center office building
V-Bank Dry Cooler Air Condenser for data center office building

Selection Data

630/800 V-Bank Air-Cooler Condenser selection data(2.11mm Fin Spacing)
Model Capacity Exchange surface Tube volume Air flow Sound Pressure Level Fan Data No. of fans Connection Weight
kW*1 L m3/h dB(A)10m 3~400/50 mm mm kg
W A N*D Inlet Outlet
HCVS163-0062 62 142 23.3 18281 61 1600 3.2 1*630 2*34.9 2*22.23 300
HCVS163-0067 67 189 31.1 17779 61 1600 3.2 1*630 2*34.9 2*22.23 325
HCVS263-0127 126 284 46.6 36539 62 3200 6.4 2*630 2*34.9 2*22.23 455
HCVS263-0140 140 378 62.1 35505 62 3200 6.4 2*630 2*34.9 2*22.23 502
HCVS363-0187 187 425 69.9 54841 63 4800 9.6 3*630 2*41.3 2*28.6 610
HCVS363-0207 207 567 93.2 53290 63 4800 9.6 3*630 2*41.3 2*28.6 679
HCVS463-0253 253 567 93.2 73079 64 6400 12.8 4*630 2*41.3 2*28.6 729
HCVS463-0280 280 756 124.3 71010 64 6400 12.8 4*630 2*41.3 2*28.6 820
HCVS563-0315 315 709 116.5 91376 65 8000 16.0 5*630 2*54 2*35 860
HCVS563-0353 353 945 155.3 88735 65 8000 16.0 5*630 2*54 2*35 980
HCVD463-0218 218 434 69.9 70363 64 6400 12.8 4*630 2*41.3 2*28.6 533
HCVD463-0250 250 578 93.2 67346 64 6400 12.8 4*630 2*41.3 2*28.6 641
HCVD663-0338 338 651 104.8 105416 66 9600 19.2 6*630 2*54 2*35 765
HCVD663-0375 375 868 139.8 101019 66 9600 19.2 6*630 2*54 2*35 873
HCVD863-0451 451 868 139.8 140554 67 12800 25.6 8*630 2*54 2*35 1025
HCVD863-0500 500 1157 186.4 134692 67 12800 25.6 8*630 2*67 2*41.3 1133
HCVD1063-0561 561 1084 174.7 175747 68 16000 32.0 10*630 2*67 2*41.3 1275
HCVD1063-0633 633 1446 233.0 168365 68 16000 32.0 10*630 2*67 2*41.3 1385
HCVD1263-0681 681 1301 209.7 210831 69 19200 38.4 12*630 2*67 2*41.3 1420
HCVD1263-0750 750 1735 279.6 202038 69 19200 38.4 12*630 2*67 2*41.3 1636
HCVD1463-0796 796 1518 244.6 245970 70 22400 44.8 14*630 2*76.3 2*54 1650
HCVD1463-0883 883 2024 326.2 235711 70 22400 44.8 14*630 2*76.3 2*54 1883
HCVD1663-0917 917 1735 279.6 281022 71 25600 51.2 16*630 2*76.3 2*54 1840
HCVD1663-1016 1016 2313 372.8 269298 71 25600 51.2 16*630 2*76.3 2*54 2135
HCVD1863-1022 1021 1952 314.5 316247 72 28800 57.6 18*630 2*76.3 2*54 2050
HCVD1863-1149 1149 2603 419.4 302863 72 28800 57.6 18*630 2*76.3 2*54 2385
HCVD2063-1282 1282 2892 466.0 336514.8 73 32000 64.0 20*630 2*89 2*54 2633
HCVD480-0251 251 510 83.9 80279 54 7200 15.2 4*800 2*41.3 2*35 735
HCVD480-0276 276 681 111.8 74879 54 7200 15.2 4*800 2*54 2*41.3 835
HCVD680-0381 381 766 125.8 120418 56 10800 22.8 6*800 2*54 2*41.3 1135
HCVD680-0413 413 1021 167.8 112318 56 10800 22.8 6*800 2*67 2*41.3 1225
HCVD880-0411 411 1021 167.8 120430 58 14400 30.4 8*800 2*67 2*41.3 1617
HCVD880-0552 552 1361 223.7 149758 58 14400 30.4 8*800 2*67 2*41.3 1753
HCVD1080-0634 634 1276 209.7 200697 60 18000 38.0 10*800 2*76.3 2*54 1894
HCVD1080-0693 693 1702 279.6 187197 60 18000 38.0 10*800 2*76.3 2*54 2042
HCVD1280-0827 827 2042 335.5 224637 62 21600 45.6 12*800 2*76.3 2*54 2327
HCVD1480-0954 954 2382 391.4 262076 64 25200 53.2 14*800 2*89 2*54 2741
HCVD1680-1104 1104 2723 447.3 299516 66 28800 60.8 16*800 2*89 2*54 2947
HCVD1880-1286 1286 3063 503.3 336576 66 32400 68.4 18*800 2*89 2*54 3342
1. Capacity based on sub-cooling 0K,ambient temp of 35℃,condensing temp of 50℃,suctio temp of 100℃,R404A..
2. The sound pressure level data are average tested at the intersection of fan plane and reflection plane 10meters from axis

OEM Customation

Frame

Fin

Heat-exchange Tube

Fan

Electric Control

Other

Hot dip galvanized steel

Hydrophilic Fin

Stainless steel 304

EC Fan

Junction Box

HT/LT Double-Bank Heat-exchange

Stainless steel 304

Almg 25

Stainless steel 316

Explosion-proof fan motors

safety Switch

Adiabatic Water spraying system

Stainless steel 316

Copper Fin

B10

Marine Fan Motor

Control Box

Steel Structure and safe access for service

Aluminum

Pre-coated Epoxy Fin

B30

Stainless Steel Guards

VFD Control Box

Air filter

Copper Tinned Fin

Titanium

Temperature/Pressure Control Box

Heresite/ Blygold/Epxoy Coated Fin

Advantages

Design software Using the mature European design software, according to the EN1048 and actual demand accurate design of heat exchanger, can design the special low temperature cold agent etc.
Heat exchange structure Supported to the casing by means of a "flating-bed " system that avoids any kind of contact between the heat-exchange tubes and the supporting end plates,assuring a long life for the heat-exchange without leaks. Heat-exchange sections separated and independent for each fan. The standard fin spacing is 2.1mm,Fin pitch up to 12mm for low air pressure drop.
Condenser structure Shape with flexible and changeable,--Flat-bed,W-Bank,V-Bank; Fan direction--blowing and sucking. Finned length up to 12m,Finned height up to 2.7m.
Heat Exchange Tube Using copper content more than 99.9% pipe,using three type copper tube 3/8",1/2",5/8" Increased the thermal efficiency and low fluid pressure drop .
Casing Using galvanized sheet case, spraying outdoor powder coatings, and after high temperature curing, high strength of corrosion resistance is strong, the standard color for RAL9003.
Fans Low noise axial fans,with maintenance free motors in protection class IP 54,Internal motor protection with thermo contacts.With precise design, forming mould processing, air volume is larger and more efficient.

Project Experience
  • 3D model drawing available
  • Prototype testing and confirmation
  • Steel frame support, Front to Back type design and manufacturing
  • Easy mounting and maintain, Good anti-vibration
  • Stable Performance & Low Pressure Drop
  • Compact Design & Light Weight
  • Motor & Fan is Optional
  • 12 Month Global Warranty
  • OEM Production is Offered

Purchasing Guide

You just need to tell us your specific requirements and environmental parameters so that we can make professional quotations accordingly.

Please advise:

Oil parameter Fluid
Flow
Inlet temperature (℃)
Cooling power (kw)
Max. allowable pressure drop
Max. work pressure (MPa)
Air parameter Flow
Inlet temperature (℃)
Cooling power (kw)
Max. allowable pressure drop
Max. work pressure (MPa)
Cool air parameter Flow & Pressure curve
Inlet temperature (℃)
Air trace
Mounting Max overall dimension
Location of connections
Requirement of structure
Working condition

Be free to contact us if you need any further information, thank you!


Product Tags:

dry cooling system

      

dry air cooler

      
Quality V-Bank Dry Cooler Air Condenser for data center office building wholesale

V-Bank Dry Cooler Air Condenser for data center office building Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Changzhou ADV Heat Exchanger Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)